Gripp Virusni universal / H1 / H3

Qisqacha tavsif:

Ushbu to'plam grippni sifatli aniqlash uchun ishlatiladi, virusni universal turdagi virus, H1 turi va H3 tipidagi nuklein kislotasi


Mahsulot tafsilotlari

Mahsulot teglari

Mahsulot nomi

HWTS-RT012 Grippga grippniversal / h1 / h3 nukleyylex-ning ko'payishi (florecececcececcececcececcececcececece)

Epidemiologiya

Gripp virusi - bu orfomikxoviridae vakili. Bu inson salomatligiga jiddiy tahdid soladigan patogendir. Bu mezbonlarga keng ta'sir qilishi mumkin. Mavsumiy epidemiya butun dunyo bo'ylab 600 millionga yaqin odamga ta'sir qiladi va ular virus infektsiya va o'limning asosiy sababidir. Gripp virus - bu bitta torli mantiqsiz reaktiv RNK. Uning yuzasi imoglutinin (Ha) va neyrainidazase (Na), gektariga to'g'ri bo'lishi mumkin. Among influenza A viruses, the subtypes of influenza viruses that can directly infect humans are: A H1N1, H3N2, H5N1, H7N1, H7N2, H7N3, H7N7, H7N9, H9N2 and H10N8. Ular orasida H1 va H3 subtypes juda patogen va ayniqsa diqqatga sazovor ahamiyatga ega.

Kanal

Fam gripp universal tipidagi virus yadro kislotasi
Vic / Hex gripp H1 turi virusi nuklein kislotasi
Rohmoq gripp H3 tipidagi virus yadro kislotasi
S5 Ichki nazorat

Texnik parametrlar

Saqlash

≤ - 18 ℃

Yaroqlilik muddati 9 oy
Namunaviy turi Nasofareheal Swab
Ct ≤38
CV ≤5.0%
Jodu 500 nusxa / mkl
O'ziga xoslik

Apreenza a, grippza b, lyukella pnevmoniya, riaovirus, respiratorli virusi, paropflüenza, Echo virusi, Metapneevirus, parazetfluenza virusi yo'q A1 / A2 / B1 / B2, nafas olish singari A / B, Coronavirus 229E / NL63 / OC43, Rinovirus A virusi 1/2/3/4, xlamiddia prokomatis, Adenovirus va boshqalar. genomik DNK.

Qo'llaniladigan vositalar Amaliy Biosystemlar 7500 real vaqt rejimida PCR tizimi

Amaliy Biosymlar 7500 REAL-SHAXSIY TARMOQDA

Kvantstudio®5 Real vaqtli PCR tizimlari

SLAN-96P real vaqtli PCR tizimlari (Xongshi tibbiyot texnologiyalari Co., Ltd.)

LightCycy® 480 real vaqt rejimida PCR tizimi

Linegenen 9600 Plus Real vaqtli PCRni aniqlash tizimi (FQD-96A, Hangjhou Bioer Technology)

Ma-6000 real vaqtli termal tsikl (Suzhou Molray Co, Ltd.)

Biorad CFX96 real vaqt rejimida PCR tizimi

Biorad CFX OPUS 96 real vaqtda PCR tizimi

Ish oqimi

Tiangen Biotex (Bemping) Co., Ltd tomonidan nuklon kislotasi yoki tozalash registrini (YDP315-R). Qazib olish foydalanish bo'yicha ko'rsatmalarga muvofiq qat'iy ravishda amalga oshirilishi kerak. Olingan namuna hajmi 140 ml va tavsiya etilgan protsedura hajmi 60 mkl.

2-variant.

MacRo & Micro-test Viral DNK (HWTS-3004-32, HWTS-3004-48) va Micro & 3006C, HWT-3006C, HWT-3006B). Qazib olish foydalanish bo'yicha ko'rsatmalarga muvofiq qat'iy ravishda amalga oshirilishi kerak. Olingan namuna hajmi 200 ml, tavsiya etilgan protsedura hajmi 80ml.


  • Oldingi:
  • Keyingisi:

  • Bu erda xabaringizni yozing va bizga yuboring