Sakkiz turdagi nafas olish viruslari

Qisqacha tavsif:

Ushbu to'plam odamning orofaringeal va nazofaringeal tampon namunalarida A grippi virusi (IFV A), B grippi virusi (IFVB), ​​respirator sinsitial virus (RSV), adenovirus (Adv), odam metapnevmovirusi (hMPV), rinovirus (Rhv), parainfluenza virusi (PIV) va Mycoplasma pneumoniae (MP) nuklein kislotalarini in vitro sifatli aniqlash uchun ishlatiladi.


Mahsulot tafsiloti

Mahsulot teglari

Mahsulot nomi

HWTS-RT184-Sakkiz turdagi nafas olish viruslari nuklein kislotasini aniqlash to'plami (floresan PCR)

Epidemiologiya

Nafas olish yo'llari infektsiyasi inson kasalliklarining eng keng tarqalgan turi bo'lib, u har qanday jins, yosh va mintaqada paydo bo'lishi mumkin va dunyodagi kasallanish va o'limning eng muhim sabablaridan biridir.[1]Klinik jihatdan keng tarqalgan respirator patogenlar qatoriga A grippi virusi (IFV A), B grippi virusi (IFV B), respirator sinsitial virus, adenovirus, odam metapnevmovirusi, rinovirus, parainfluenza virusi (I/II/III) va mikoplazma pnevmoniyasi kiradi.[2,3]Nafas olish yo'llari infektsiyasi keltirib chiqaradigan klinik alomatlar va belgilar nisbatan o'xshash, ammo turli patogenlar keltirib chiqaradigan infeksiya turli xil davolash usullariga, shifobaxsh ta'sirga va kasallikning kechishiga ega.[4,5]Hozirgi vaqtda nafas olish yo'llari patogenlarini laboratoriyada aniqlashning asosiy usullari quyidagilarni o'z ichiga oladi: virusni ajratish, antigenni aniqlash va nuklein kislotani aniqlash. Ushbu to'plam nafas olish yo'llari infektsiyasining belgilari va alomatlari bo'lgan shaxslarda o'ziga xos virusli nuklein kislotalarni aniqlaydi va boshqa klinik va laboratoriya natijalari bilan birgalikda nafas olish yo'llari virusli infektsiyasini tashxislashda yordam beradi.

Texnik parametrlar

Saqlash

2-8℃

Yaroqlilik muddati 12 oy
Namuna turi Og'iz-halqum tampon; Nazofaringeal tampon
Ct IFV A, IFVB, RSV, Adv, hMPV, Rhv, PIV, MP Ct≤35
CV <5.0%
LoD 200 nusxa/ml
O'ziga xoslik

O'zaro reaktivlik: Kit va Boka virusi, Sitomegalovirus, Epstein-Barr virusi, Herpes simplex virusi, Varicella zoster virusi, Tepki virusi, Enterovirus, qizamiq virusi, inson koronavirusi, SARS koronavirusi, MERS koronavirusi, Rotavirus, Norovirus, Chlamydia pneumoniae, Streptococcus pneumoniae, Klebsiella pneumoniae, Streptococcus pyogenes, Legionella, Pneumospora, Haemophilus influenzae, Bacillus pertussis, Staphylococcus aureus, Mycobacterium tuberculosis, gonococcus, Candida albicans, Candida glabra, Aspergillus fumigatus, Cryptococcus neoformans, Streptococcus salivarius, Moraxella catarrh, Lactobacillus, Corynebacterium, inson genom DNKsi o'rtasida o'zaro reaktivlik yo'q.

Interferensiya testi: Musin (60 mg/ml), inson qoni (50%), benefrin (2 mg/ml), gidroksimetazolin (2 mg/ml) 2 mg/ml), 5% konservantli natriy xlorid (20 mg/ml), beklometazon (20 mg/ml), deksametazon (20 mg/ml), fluniatseton (20 mkg/ml), triamsinolon (2 mg/ml), budesonid (1 mg/ml), mometazon (2 mg/ml), flutikazon (2 mg/ml), gistamin gidroxlorid (5 mg/ml), benzokain (10%), mentol (10%), zanamivir (20 mg/ml), peramivir (1 mg/ml), mupirosin (20 mg/ml), tobramitsin (0.6 mg/ml), oseltamivir (60 ng/ml), ribavirin (10 mg/L), natijalar shuni ko'rsatdiki, yuqoridagi konsentratdagi aralashuvchi moddalar

Amaldagi asboblar I turdagi aniqlash reagentiga tegishli: Applied Biosystems 7500 Real-Time PCR Systems, QuantStudio®5 ta real vaqt rejimidagi PZR tizimlari, SLAN-96P real vaqt rejimidagi PZR tizimlari (Hongshi Medical Technology Co., Ltd.), LineGene 9600 Plus real vaqt rejimidagi PZR aniqlash tizimlari (FQD-96A, Hangzhou Bioer texnologiyasi), MA-6000 real vaqt rejimidagi miqdoriy termal sikler (Suzhou Molarray Co., Ltd.), BioRad CFX96 real vaqt rejimidagi PZR tizimi, BioRad CFX Opus 96 real vaqt rejimidagi PZR tizimi.

II turdagi aniqlash reagentiga tegishli: Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. tomonidan ishlab chiqarilgan EudemonTM AIO800 (HWTS-EQ007).

Ish oqimi

Makro va mikro-test virusli DNK/RNK to'plami (HWTS-3017) (uni Makro va mikro-test avtomatik nuklein kislota ekstraktori (HWTS-3006C, HWTS-3006B) bilan ishlatish mumkin) va Makro va mikro-test virusli DNK/RNK to'plami (HWTS-3017-8) (uni Eudemon bilan ishlatish mumkin)TM AIO800 (HWTS-EQ007)) Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. tomonidan ishlab chiqarilgan.

Ekstraksiya qilingan namuna hajmi 200 mkL va tavsiya etilgan elyutatsiya hajmi 150 mkL.