12 turdagi nafas olish patogenlari
Mahsulot nomi
HWTS-RT071A 12 turdagi nafas olish patogenlari nuklein kislotasini aniqlash to'plami (floresan PCR)
Kanal
| Kanal | hu12Reaksiya buferi A | hu12Reaksiya buferi B | hu12Reaksiya buferi C | hu12Reaksiya buferi D |
| FAM | SARS-CoV-2 | HADV | HPIV III | HRV |
| VIC/HEX | Ichki nazorat | Ichki nazorat | HPIV II | Ichki nazorat |
| CY5 | IFV A | MP | HPIV 3 | / |
| ROX | IFV B | RSV | HPIV Ⅳ | HMPV |
Texnik parametrlar
| Saqlash | ≤-18℃ |
| Yaroqlilik muddati | 12 oy |
| Namuna turi | Orofaringeal tampon |
| Ct | ≤38 |
| CV | ≤5.0% |
| LoD | SARS-CoV-2:300 nusxa/mlB grippi virusi:500 nusxa/mlA grippi virusi:500 nusxa/ml Adenovirus:500 nusxa/ml mycoplasma pneumoniae:500 nusxa/ml nafas olish sinxitial virusi:500 nusxa/ml, Paragripp virusi (Ⅰ, Ⅱ, Ⅲ, Ⅳ):500 nusxa/ml Rinovirus:500 nusxa/ml inson metapnevmovirusi:500 nusxa/ml |
| O'ziga xoslik | O'zaro reaktivlik tadqiqoti shuni ko'rsatadiki, ushbu to'plam va A, B, C, D enteroviruslari, epstein-barr virusi, qizamiq virusi, odam sitomegalovirusi, rotavirus, norovirus, tepki virusi, suvchechak-gerpes zoster virusi, bordetella ko'kyo'tal, streptococcus pyogenes, mycobacterium tuberculosis, aspergillus fumigatus, candida albicans, candida glabrata, pneumocystis jirovecii, cryptococcus neoformans va inson genom nuklein kislotasi o'rtasida o'zaro reaktivlik yo'q. |
| Amaldagi asboblar | Amaliy Biosistemalar 7500 real vaqt rejimida PZR tizimlariAmaliy Biosistemalar 7500 Tezkor Haqiqiy Vaqtinchalik PZR TizimlariQuantStudio®5 ta real vaqt rejimidagi PCR tizimlari SLAN-96P real vaqt rejimida PCR tizimlari (Hongshi Medical Technology Co., Ltd.) LightCycler®480 real vaqt rejimida PCR tizimi, LineGene 9600 Plus real vaqt rejimida PCR aniqlash tizimi (FQD-96A, Hangzhou Bioer texnologiyasi) MA-6000 real vaqt rejimida miqdoriy issiqlik sikleri (Suzhou Molarray Co., Ltd.) BioRad CFX96 real vaqt rejimida PZR tizimi BioRad CFX Opus 96 real vaqt rejimida PCR tizimi |
Ish oqimi
1-variant.
Tavsiya etilgan ekstraksiya reaktivi: Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. tomonidan ishlab chiqarilgan Makro va Mikro-Test Namuna Release Reagent (HWTS-3005-8)., Ekstraksiya ko'rsatmalarga qat'iy muvofiq amalga oshirilishi kerak.
2-variant.
Tavsiya etilgan ekstraksiya reaktivi: Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. tomonidan ishlab chiqarilgan Macro & Micro-Test General DNK/RNK to'plami (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) va Macro & Micro-Test avtomatik nuklein kislota ekstraktori (HWTS-3006C, HWTS-3006B), ekstraksiya qat'iy ko'rsatmalarga muvofiq amalga oshirilishi kerak. Tavsiya etilgan elyutatsiya hajmi 80 mkL.
3-variant.
Tavsiya etilgan ekstraksiya reaktivi: Tiangen Biotech (Pekin) Co., Ltd. tomonidan ishlab chiqarilgan Nuklein kislotasini ekstraksiya qilish yoki tozalash to'plami (YDP315), ekstraksiya qat'iy ko'rsatmalarga muvofiq amalga oshirilishi kerak. Tavsiya etilgan elusiya hajmi 100 mkL.